2007年6月18日 首页

  最新公告
 


  产品展示 > UPS > 爱克赛 系列
 
Eaton EX UPS

Eaton EX Technical Specs

 Part Numbers
Technical Specifications 700 1000 - 1000 RT2U 1500 - 1500 RT2U 2200 3000 - 3000 XL
Rating (VA/W) 700 VA / 630 W 1000 VA / 900 W1 1500 VA / 1350 W1 2200 VA / 1980 W 3000 VA / 2700 W1
Format Mini tower Mini tower or RT2U (tower/rack 2U) RT2U (tower / rack 2U) and RT3U (tower / rack 3U)
Electrical characteristics
Architecture On-line double conversion with automatic by-pass and power factor correction
Input voltage and frequency ranges without using batteries 100/120/140/160 V(2) to 284V - 40 to 70 Hz 100/120/160/184 V(2) to 284V - 40 to 70 Hz
Output voltage and frequency 230 V (adjustable to 200/208/220/240/250 V), 50/60 Hz auto-select or frequency converter mode 230 V (adjustable to 200/208/220/240 V), 50/60 Hz auto-select or frequency converter mode
Connections
Input 1 IEC C14 (10A) socket IEC C20 (16A) or terminal block on HotSwap MBP HW (Hard-Wired)
Outputs 6 IEC C13 (10A) sockets 8 IEC C13 (10A) sockets + 1 IEC C19 (16A) socket
Remotely controlled Powershare sockets 2 independent groups: 2 + 1 IEC C13 (10A) sockets 2 groups of 2 x IEC C13 (10A) on Eaton EX
Additional outputs with HotSwap MBP FR/DIN/BS/IEC/HW 4 FR/Schuko sockets or 3 BS sockets or 6 IEC 10A sockets or terminal blocks (HW version)
Additional outputs with FlexPDU FR/DIN/BS/IEC 8 FR/Schuko sockets or 6 BS sockets or 12 IEC 10A sockets
Battery
Typical backup times for 50 and 70% load (6) except for Eaton EX 3000 XL5
EX 16 min / 10 min 18 min / 12 min 13 min / 9 min 17 min / 12 min 15 min / 10 min
EX + 1 EXB / 75 min / 50 min 50 min / 35 min 85 min / 60 min 60 min / 40 min
EX + 4 EXB / 250 min / 200 min 180 min / 120 min 285 min / 200 min 190 min / 150 min
Battery management Automatic weekly test (period adjustable using LCD display or in software supplied), automatic recognition of external battery units => continuous maximisation of backup time + deep discharge protection
Interfaces
Indicators and display 3 LEDS + adjustable multilingual display: display of measurements, access to control and set-up menus
Communication ports 1 USB port + 1 RS232 serial port and relay contacts4 + 1 mini terminal block for remote ON/OFF and emergency stop
Communications card slots 1 slot for NMC Minislot card (included in Netpack version) or NMC ModBus/JBus or MC Contacts/Serial
Operating conditions, standards and approvals
Operating temperature noise level 0°C to 40°C continuous, 45 dBA
Performance - Safety - EMC IEC/EN 62 040-3 (VFI-SS-113), IEC/EN 62 040-1-1, IEC/EN 60 950-1 (RD), IEC/EN 62 040-2 C1 Class
Approvals CE, TüV GS, CB report, cTüV-US CE, TüV, CB Report, UL
Dimensions W x H x D / Weight
EX 242 x 153 x 440 mm / 12.5 kg 242 x 153 x 440 mm / 15 kg 242 x 153 x 440 mm / 18 kg 131 x 440 x 490 mm (compatible with 600 mm deep rack) / 30 kg (3000 XL = 18 kg)
EX RT2U / 86.5 x 438 x 483 mm / 18 kg 86.5 x 438 x 483 mm / 20.5 kg 86 x 440 x 640 mm / 31 kg
EX EXB / 242 x 153 x 440 mm / 21 kg 131 x 440 x 490 mm (compatible with 600 mm deep rack) / 42 kg
EX EXB RT2U / 86.5 x 438 x 483 mm / 24.5 kg / /
Customer Service & Support
2 years warranty Standard product exchange, including the battery
Warranty+ Optional 3-years warranty (depending on the country please visit www.eaton.com/powerquality )

1: Maximum rating with EXB battery units: Eaton EX 1000 = 800 W, Eaton EX 1500 =1200 W and Eaton EX 3000=2400W.
2: Lower limits for <20%, <33%, <66%, >=66% of nominal power (VA). For active output power greater than 0.7 and 0.8 nominal rating, the lower limit is 180V and 190V respectively.
3: Derated by 15% when used as a frequency converter.
4: USB and RS232 serial ports cannot be used simultaneously.
5: Except Eaton EX 3000 XL: UPS with high speed charger, without built-in batteries, for custom configurations: ask us for details.
6: Runtimes are shown at 0.7 power factor. Backup times are approximate and may vary with equipment, configuration, battery age, temperature, etc.

Go to top

Part Numbers

Part Numbers 700 1000 1500 2200 3000
EX 68 180 68 181 68 183 68 400 68 402 - XL: 68 404
EX RT2U (includes rack kit) / 68 182 68 184 68 401 68 403
EX RT3U HotSwap.
(Eaton EX RT3U HotSwap =
Eaton EX RT + rack kit + HotSwap MBP)
/ / / FR: 68 406 DIN: 68 407
BS: 68 408 IEC: 68 409
HW: 68 410
FR: 68 412 DIN: 68413
BS: 68 414 IEC: 68 415
HW: 68 416
EX RT2U Netpack (includes rack kit and NMC card) / / / 68 411 68 417
EX EXB / 68 185 68 185 68 405 68 405
EX EXB (includes rack kit) / 68 186 68 186    
EX Rack Kit 2U/3U / / / 68 441 68 441



  版权所有@北京宏华创业科技发展有限公司 电话:010-51292274、80709454、80709644、80709564
传真:010-80709414 京ICP备05044358号地址:北京市海淀区科学院南路新科祥园9号楼21层 邮编:100191
Email:chendan517@126.com Powered by SomooWms